New ZEISS IOL Master 500

The ZEISS IOL Master  500 is the gold standard in optical biometry with more than 100 million successful IOL power calculations to date. With the new version of the ZEISS IOL Master 500, you get a piece of cutting-edge technology that points the way to the future of optical biometry.

[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/1″ css=”.vc_custom_1449686289026{border-width: 2px !important;padding: 2px !important;background-color: #ededed !important;}”][vc_tabs][vc_tab title=”Highlights” tab_id=”1450209362-1-48″][vc_column_text]

Improving Refractive Outcomes

Any intraocular lens calculation is only as reliable as the lens constant it is based on. More than 40,000 sets of patient data created with the ZEISS IOL Master are the basis of more than 200 optimized lens constants in the User Group for Laser Interference Biometry (ULIB) website – absolutely unique in the industry.1 Together with its one-of-a-kind distance independent telecentric keratometry and the exclusively integrated Holladay 2 formula, the gold standard in optical biometry helps you improve your refractive outcomes.2

Markerless Toric IOL Alignment

The new Option Reference Image is the starting point of a markerless toric IOL workflow: an image of the eye is taken along with the keratometry measurement. Both, reference images and keratometry data are transferred to the ZEISS CALLISTO eye® computer-assisted surgery system. Finally, all data needed for precise5 and markerless toric IOL alignment is injected into the eyepiece of the surgical microscope from ZEISS.

Advanced Measurement of Challenging Eyes

The true test of a biometer is its performance with challenging eyes. In denser cataracts, the ZEISS IOL Master 500 achieves a measurement success ratio that is up to 20% higher than that of other optical biometry devices.3 Even with staphyloma, pseudophakic and silicone-filled eyes, the ZEISS IOL Master 500 measures along the visual axis, yielding the relevant axial distance. And with its Haigis-L formula on board the ZEISS IOL Master 500 is dedicated to myopic and hyperopic post-LVC cases.

Proven Toric Outcomes

The results of a meta-analysis of 28 published clinical papers covering more than 1900 cases show that the reported clinical outcomes for the ZEISS IOL Master with regard to residual astigmatism “[…] exceed, or are at least as good as those using manual or automated keratometry.”4

Ease of Use

A well-designed user interface, plausibility checks, distance-independent measurements and an up to 4 times faster reading compared to other optical devices lead to a one-of-a-kind usability and reduced chair time. A difference you, your team and your patients will notice every day.[/vc_column_text][/vc_tab][vc_tab title=”Specifications” tab_id=”1450209362-2-55″][vc_column_text]

Measurement Range

  • Axial length 14 – 38 mm
  • Corneal radii 5 – 10 mm
  • Anterior chamber depth 1.5 – 6.5 mm
  • White-to-white 8 –16 mm

Display Scalling

  • Axial length 0.01 mm
  • Corneal radii 0.01 mm
  • Anterior chamber depth 0.01 mm
  • White-to-white 0.1 mm

IOL Calculation Formulas

  • SRK II, SRK/ T, Holladay 1 and 2, Hoffer Q, Haigis
  • Clinical history and contact lens fitting method forcalculation of corneal refractive power following refractive corneal surgery
  • Haigis-L IOL calculation for eyes following myopic /hyperopic LASIK / PRK / LASIK surgery
  • Calculation of phakic anterior and posterior chamberimplants
  • Optimization of IOL constants

Interfaces

  • Ultrasound data link (to Accutome A-Scan synergy)
  • ZEISS data archive and review solution FORUM
  • ZEISS OR management system CALLISTO eye
  • Data interface for electronic medical record (EMR) /patient management systems (PMS)
  • Data export to USB storage media
  • Export database for Holladay IOL Consultant and HIC.SOAPPro
  • Ethernet port for network connection and network printer
  • Line voltage     100– 240 V ± 10 % (self-sensing)

Line Frequence

  • 50 – 60 Hz

Performance Consumption

  • Max. 75 VA